The Special Boiler Design Bureau



STEAM AND HOT WATER WASTE HEAT RECOVERY BOILERS

йсо 180, йсо2500, йсо5000 waste heat recovery boilers and йсб8 hot water boiler are designed to improve the cost efficiency of heal-and-power plants (diesels and gas turbines) and also to recover heat of different production processes. They are used to generate saturated steam (йсо 180), superheated steam (йсо2500, йсо 5000) and hot water (йсб8).

The boilers meet the requirements of Gosgortcchnadzor of Russian Federation.

The waste heat recovery boilers are fitted up with steam separators, feed and circulating pumps and control system.

The hot water waste heat recovery boiler KVB8 may be supplied together with circuit pumps at the Customer's request

The reiterative forced circulation is envisaged in waste heat recovery boilers.

Gas flow (inlet ant outlet) in the boilers may be reversed depending on the mounting conditions of the power plant.

The heating surfaces of coiled steam boilers are arranged of spiral finned tubes and those of йсо80 boiler are arranged of plain tubes.

I he control system comprises adjusting, remote-operated and shutoff accessories, sensors and instrumentation for remote and local parameters control and ensures the entire boiler control within the whole automatic control system of power plant.

The quality of feed water should comply with the maintenance directives.

Tile waste heat recovery boilers are supplied by modules convenient for transportation. The modules may be delivered by ship, railway or trucks (except йсо 2500 boiler).

"SKBK" JSC ensures supervision, setting up, start up, personnel training, warranty and post-warranty maintenance of the boiler.

CONSTRUCTION LAYOUT OF WASTE HEAT RECOVERY BOILERS


   йсо500 steam boiler
   1 - economizer bank
   2 - steam-generating banks
   3 - superheater bank



   йсо2500 steam boiler
   1 - superheater bank
   2 - steam-generating banks
   3 - economizer bank



   йсо180 steam boiler
   1 - steam-generating bank



   йсб8 hot water boiler
   1 - hot water banks



TECHNICAL DATA OF THE BOILERS

Parameters йсо180 йсо2500 йсо5000 йсб8
Steam output, t/h 2.1 9-12 26-39 -
Steam pressure, MPa 0.8 1.3 1.8 -
Steam temperature, ╟C 175 275 280
Heat output, MW - - - 7-10
Outlet pressure of circuit water, MPa - - - up to 2.5
Outlet temperature of circuit water, C - - - up to 150
Hue gas path resistanse at the boiler, Pa 800 2200 4000 1750
Gas inlet temperature at the boiler, C 440 360 536 350
Gas outlet temperature at the boiler, C 235 175 146 95
Gas rate per a boiler, Kg/s 6.82 35.4 82 31.5
Inlet water pressure at the boiler, MPa 0.9 1.4 2.1 2.35
Inlet water temperature at the boiler, C 50 104 60 55
Water rate, m3/h - - - 160
Boiler overall dimensions, mm:        
        width 2375 4680 3750 4265
        length 2910 3640 6715 3700
        height 4800 5450 6020 4580
Mass of dry boiler, t 7.75 36.6 65.0 32.0
Number of modules to be supplied, ps 2 2 3 2

Note: The steam output and heat output may be varried in accordance to gas rate and temperature.


BOILERS' ADVANTAGES

  1. The scope of works to be carried out for heat-and-power plants construction and renovation is cut down essentially owing to the small boiler sizes.
  2. It lakes not more than 2 or 3 days to install the boiler on the basements got ready in advance.

These boilers have been developed on the base of waste heal recovery boilers originally designed by "SKBK" JSC and being widely used since 60-es.



The main development and delivery contractor is
"The Special Boiler Design Bureau", JSC
2, 23rd Line, Saint-Petersburg, 199106, Russia
Fax (812) 327-70-25, (812) 327-70-28
Phone (812) 322-23-77
E-mail: info@skbk.ru



The Special Boiler Design Bureau